Palmer Woods Heating & AC, home

Heating Repair

Heating repair covers the two machines that keep most houses warm: the gas furnace, which blows heated air through ducts, and the boiler, which sends hot water or steam to radiators.

Detroit’s older houses often heat with a boiler and radiators; newer and updated ones mostly run a gas furnace. Either way, a repair starts with what the system is doing and since when.

Furnace and Boiler Faults by Symptom

Furnace and Boiler Symptoms
SymptomPossible causesWhat to note before calling
No heat at all A thermostat setting or dead batteries; the service switch or breaker off; a failed igniter, pilot or gas valve; a tripped low-water cutoff Whether the display is lit, and what you hear on a call for heat
Furnace runs, air blows cold Burners dropping out on a dirty flame sensor; a high-limit trip from a clogged filter; a plugged condensate trap Cold from the start or after a few minutes; the fan setting
Short cycling A dirty flame sensor; overheating from a clogged filter; snow over a sidewall vent; a thermostat by a supply register Minutes per run; whether the blower runs on after the burners stop
One room cold, the rest warm A closed register; a leaking or loose duct; no return air; trapped air in a radiator Which room and floor; always cold, or new this season
Squeal, rattle or a boom A worn blower motor or loose blower wheel; a loose panel; delayed ignition from dirty burners Start-up, running or shut-off; after a boom, switch the furnace off
Boiler pressure high or low A waterlogged expansion tank; a fill valve sticking or leaking through; a leak in the piping The gauge cold and hot; any water at the relief valve
Radiators cold or banging Air in the radiators; a stopped circulator pump or zone valve; a steam pipe that has lost its pitch Which radiators, and whether the noise comes as the heat starts
Blinking light or fault code The control board naming a failed step: pressure switch, igniter, flame sensor or limit switch The blink count and pattern, read against the chart inside the furnace door

Why does the furnace run but blow cold air?

Usually the burners lit, then went out while the blower ran on. A flame sensor coated with residue cannot prove the flame, so the board shuts the gas off; a clogged filter trips the high-limit switch the same way, and so can a plugged condensate trap. Check the thermostat fan first: set to On, it blows unheated air between cycles.

Why does the furnace start, run a few minutes and shut off?

That is short cycling, usually from a dirty flame sensor, a high-limit switch tripping on too little airflow, or a blocked intake or exhaust pipe; a thermostat beside a supply register can cut cycles short too. The restarts wear out the igniter and the inducer motor, so it is worth a call before those parts fail.

Why are some rooms cold while others stay warm?

Warm air takes the easy path: rooms at the end of long duct runs, over a garage or without a return get less of it, and leaky basement trunk lines drop heat where nobody sits. Sealing joints, adding a return and balancing dampers usually even it out. Upstairs in a story-and-a-half bungalow, thin knee walls lose heat that no furnace adjustment can make up.

Is a boiler that bangs or gurgles something to call about?

Gurgling in a hot-water system is usually air, and bleeding the radiators often clears it. Banging deserves a call: on steam it usually means water trapped in a pipe that has lost its pitch, and on a hot-water boiler it can mean scale on the heat exchanger flashing water to steam. So does a gauge climbing toward 30 psi or a dripping relief valve.

Safe Checks Before You Call

  • Thermostat settings. Mode on Heat, the setpoint a few degrees warmer than the room, fresh batteries, and no hold or schedule overriding it.
  • The furnace power switch. It looks like a light switch, often with a red cover plate, on or near the furnace or boiler, and it is easy to flip off by mistake.
  • The filter. A clogged filter starves the furnace of air until the high-limit switch shuts the burners off. If light does not pass through it, replace it.
  • The breaker. Reset a tripped breaker once. If it trips again, leave it off: it is reacting to a fault, and repeated resets put the wiring and the equipment at risk.

A Gas Smell Overrides Every Check

For a rotten-egg smell or a carbon monoxide alarm, get everyone out, then call DTE Energy and 911 from outside, without touching light switches or equipment on the way.

A Furnace Lights in a Fixed Order

High-efficiency gas furnace with white PVC vent pipes and a sheet-metal plenum in a basement laundry corner

On a call for heat, a gas furnace runs a fixed sequence: the inducer motor clears the flue, a pressure switch proves the draft, the igniter glows, the gas valve opens, and the flame sensor has seconds to see flame before the board shuts the gas off. Only then does the blower start, and a failure at any step stops the furnace with a blinking code.

High-efficiency furnaces, the ones with white plastic vent pipes, also drain water through a condensate trap. A sludgy trap or a dirty flame sensor is the kind of wear a fall heating tune-up catches early.

A Cracked Heat Exchanger Changes the Question

A cracked heat exchanger can leak combustion gases, carbon monoxide among them, into the air the blower moves through the house, and replacing that part alone rarely makes sense. A furnace past fifteen or twenty years with several worn parts, or a leaking cast-iron boiler section, points the same way: toward replacing the furnace or boiler.

Call About the Furnace or Boiler

Call or send a request with the symptom, any blink code or boiler pressure reading, and the address.