Air Conditioning
Air conditioning repair covers central air conditioners and heat pumps, ductless units included: the equipment that pulls heat and water out of a house through a humid Detroit summer.
A central system has two halves joined by a copper line set: the outdoor condenser, holding the compressor, a fan and a coil that sheds heat, and the indoor evaporator coil on the furnace, where the house air gives up heat and water. A heat pump adds a reversing valve to heat in winter, and its winter faults are air conditioning repairs too. Ductless units put the indoor coil in a slim head on the wall.
Where Cooling Trouble Usually Starts
| Symptom | Possible causes | What to note before calling |
|---|---|---|
| Running but not cooling | A clogged filter or dirty coil; refrigerant low from a leak; an outdoor unit stopped by a breaker, contactor or capacitor | Whether the outdoor unit runs while the indoor blower does |
| Ice on the line set or coil | Too little air across the indoor coil (filter, closed registers, a weak blower) or too little refrigerant | Where the ice sits and when the filter was last changed |
| Water around the indoor unit or furnace | A clogged condensate line; a cracked drain pan; a failed condensate pump; a coil thawing after icing | Whether water appears while the system runs or after it stops |
| Outdoor unit hums, fan still | A failed capacitor; a seized fan motor; a contactor with burnt contacts | Whether the breaker tripped; then switch it off at the thermostat |
| Short cycling | Equipment too large for the house; a dirty condenser coil or weak capacitor overheating the compressor; a pressure switch tripping on low refrigerant | Minutes per run, and whether the indoor blower stops with the outdoor unit |
| One room’s vents blow warm | A long, crushed or disconnected duct run; a closed damper; a top-floor room gaining heat through the roof | Which room and floor; always warm, or new this summer |
| Ductless head dripping or blinking | A clogged drain line from the head; dirty filters icing the coil; a fault code from the control board | The blink count or display code, and the model number from the head’s label |
| Sticky, humid air indoors | An oversized system that shuts off before the water is out; the fan set to On; a low charge | The indoor humidity if a gauge is at hand; 40 to 50 percent is a usual summer target |
Why is the air conditioner running but the house not cooling down?
Start with the air: a clogged filter or dirty evaporator coil cuts airflow, and a matted condenser coil cannot shed heat. A silent outdoor unit with the blower running points to a capacitor, a contactor or a tripped breaker; air that is barely cool with everything running points to a leak. On the hottest, most humid afternoons, even a well-sized system can fall a few degrees behind.
Why is there ice on the copper line or the indoor coil?
The coil has gotten cold enough to freeze the water on it, because too little warm air crosses it or the system is low on refrigerant. Switch the cooling off and run the fan alone until the ice melts, watching the drain pan. If the ice returns with a clean filter and open registers, the refrigerant side needs a technician.
Is water around the furnace in summer coming from the air conditioner?
Usually, yes. The evaporator coil sits on the furnace, and its water drains through a condensate line to a floor drain or a small pump. When sludge clogs that line, the pan overflows down the furnace cabinet, or a float switch shuts the cooling off, which looks like a failed air conditioner.
Should I keep running the air conditioner if the outdoor unit hums but the fan does not turn?
No. Switch it off at the thermostat. A hum with a still fan usually means a failed capacitor or a seized fan motor, and the compressor overheats quickly with no air moving across the coil; a capacitor is a small part, a compressor a far bigger job. Leave the panel closed: a capacitor holds a charge even with the power off.
Rule Out the Simple Causes
- Thermostat mode. Cool, with the fan on Auto and the setpoint a few degrees cooler than the room.
- The breaker and the outdoor disconnect. The breakers for the outdoor unit and the furnace, and the disconnect box on the wall by the outdoor unit. Reset a tripped breaker once only.
- The filter. A clogged filter often causes an iced coil, and long summer run hours clog it sooner than the package suggests.
- Clear space around the outdoor unit. About two feet on every side, with no leaves, cottonwood fluff, shrubs or a winter cover left on.
Much of what fails in a heat wave starts as spring dirt and wear: a matted condenser coil, a sludgy drain line, a weak capacitor. A spring cooling tune-up deals with those while the weather is mild.
A Low Charge Means a Leak
Refrigerant is not used up like fuel. A system that is low has a leak: a line set rubbed through where it crosses a sill, a corroded evaporator coil, a loose flare fitting at a ductless head. Topping it up without finding the leak is a stopgap, and the charge drains away again, in weeks or over a season.
Finding the leak means testing joints and coils with an electronic detector or bubble solution, sometimes with the system held under nitrogen pressure. Section 608 of the federal Clean Air Act governs who may handle refrigerant and forbids venting it into the air, so the work belongs to a technician with recovery equipment.
Say What the Outdoor Unit Is Doing
Running, humming or silent: that one detail narrows a cooling fault. Call or send a request with it, the thermostat setting and the address.