Our Standards
Sound heating and cooling work follows an order: find the cause, explain the fix, do the work to the code and the maker’s instructions, and prove the system runs safely before calling it done.
Each step rests on the one before. One complaint, a furnace that will not heat, can come from a dirty flame sensor, a failed igniter or a plugged condensate trap, and swapping parts until the symptom stops can leave the real fault in place.
A Diagnosis Comes Before the Parts
A sound assessment checks what the system does against what it should do, step by step through its sequence of operation.
| Job type | What is looked at | What the findings decide |
|---|---|---|
| A furnace that will not heat | The thermostat call, the ignition sequence (inducer, pressure switch, igniter, flame sensor), error codes, filter, condensate trap and vent pipes | The fix that restores heat, or replacement if the heat exchanger has failed |
| A boiler problem | System pressure, expansion tank, circulator pump, zone valves, low-water cutoff, trapped air, burner and flue | Purging air, a new tank, pump or valve, or a new boiler |
| Central air not cooling | Breaker and disconnect, capacitor and contactor, outdoor fan, filter and airflow, evaporator coil, condensate drain, refrigerant pressures | A starting part, a cleaning, a drain repair, or a leak search before refrigerant goes in |
| A replacement estimate | A load calculation, duct sizes and static pressure, the vent route, gas line, electrical circuit, and the way in and out | The size and type of the new equipment, and what must change around it |
| Uneven rooms and ductwork | Register temperatures, return paths, static pressure, duct leakage, dampers and long runs | Balancing, sealing, a new return or a rerouted branch |
| A thermostat install | Wiring at the wall and at the equipment, the number of stages, a heat pump’s extra wires, and placement | The right thermostat, any new wire, and its spot on the wall |
A Job Runs in Stages
Repairs and replacements pass through the same stages, though a repair may finish several in one visit.
| Stage | What generally happens | What the customer may be asked |
|---|---|---|
| First call | The problem and the address are noted, and a time is set | What the system is doing, when it started, and how to reach the equipment |
| Walk-through and diagnosis | Equipment, venting and ducts or piping are inspected and tested until the cause is found | Where the equipment is, and which rooms run hot or cold |
| Estimate | The work is written up item by item, with options where real ones exist | Questions about any line, and a choice between repair and replacement |
| Permit and preparation | For a replacement, permits are taken out and the equipment ordered | A work day, and a clear path to the equipment |
| The work | Old equipment comes out and the new is set, piped, wired and vented, or the repair is made | Children and pets kept clear of the work area |
| Startup, testing and inspection | Full cycles run while gas pressure, combustion, temperatures, charge and safety controls are checked; permitted work is inspected | Access for the inspector, and the paperwork kept with the house records |
Testing is where the work proves itself. In sound work, a furnace runs long enough to show a steady temperature rise inside the range on its rating plate. An air conditioner’s refrigerant charge is set by measured superheat or subcooling, not by the feel of a cold pipe. A new thermostat goes through every call it can make: heat, cooling, fan, and on a heat pump the backup heat as well.
The safety controls are tested too: limit and rollout switches, a boiler’s low-water cutoff, the float switch in a condensate pan. A control that has been bypassed or jumped out is a hazard, never a repair.
At Palmer Woods Heating & AC, those stages carry habits of the company’s own: an estimate written after a walk-through of the house and explained line by line, drop cloths laid before work begins, the area swept before the visit ends, a call when the schedule shifts, and a short summary of what was done once the visit is over.
Codes Govern Gas, Venting, Refrigerant and Wiring
Equipment that burns fuel, holds refrigerant under pressure and draws heavy electrical loads answers to the codes Michigan adopts, to federal refrigerant law and to each maker’s installation instructions.
| Area | Rule or standard that applies | What it means for the homeowner |
|---|---|---|
| Gas and combustion | The fuel gas code Michigan adopts and the maker’s instructions: sized, leak-tested piping, combustion air, draft, and carbon monoxide measured in the flue gas | A closed-in furnace room may need openings for air; a carbon monoxide alarm backs up a sound installation, never replaces one |
| Venting | Vent size, material and route by the mechanical and fuel gas codes and the maker’s instructions; high-efficiency furnaces vent through PVC, and a water heater left alone in an oversized chimney usually needs a liner | A furnace upgrade can change how the water heater vents, and vent ends outside need clearance from windows, doors and drifting snow |
| Refrigerant handling | Section 608 of the federal Clean Air Act, enforced by the EPA: refrigerant is recovered, never vented, by technicians who have passed the EPA exam | Recharging is not a homeowner job, and an old unit’s refrigerant is recovered before the unit is scrapped |
| Electrical | The National Electrical Code as Michigan adopts it: a circuit of its own for the condenser, sized to its nameplate, and a disconnect within sight of the unit | A new or larger condenser may need new wire, a different breaker or a new disconnect |
| Permits and inspections | A mechanical permit for new or replacement equipment from the city or township building department (in Detroit, BSEED), plus an electrical permit for new wiring | An inspector checks the finished work and needs access to it; the permit record belongs with the house papers |
Does replacing a furnace or an air conditioner need a permit?
Generally, yes. In Michigan, installing or replacing a furnace, boiler, central air conditioner or heat pump needs a mechanical permit from the local building department: the Buildings, Safety Engineering and Environmental Department (BSEED) in Detroit, the city’s own department in the suburbs, or the state where a community runs none. A new circuit usually adds an electrical permit, while a small part swap such as an igniter generally needs none.
Who is allowed to handle refrigerant?
Under Section 608 of the federal Clean Air Act, only technicians who have passed an EPA-approved exam may open a refrigerant circuit, recover refrigerant or recharge a system, and the sale of most refrigerants is limited to them. Knowingly venting refrigerant breaks federal law, so leaks and recharges are a technician’s work.
Where should carbon monoxide alarms go?
The International Residential Code, the model for Michigan’s residential code, calls for a carbon monoxide alarm outside each sleeping area, close to the bedrooms, in homes with fuel-burning appliances or an attached garage. Fire-safety guidance adds one on every level, basement included. Mount each as its maker directs, away from the furnace itself, steamy bathrooms and the garage, and replace it by its printed date.
What happens during a combustion safety check?
The technician inspects the burner flame and the heat exchanger, measures carbon monoxide, oxygen and temperature in the flue gas with a combustion analyzer, and checks the gas pressure against the rating plate. On a natural-draft appliance such as an older water heater, draft is tested at the draft hood, often with the exhaust fans and the dryer running, to catch spillage. Room air is checked for carbon monoxide too.
Everyday questions, such as a radiator that stays cold at the top or the filter rating to buy, have their own Questions and Answers.
Warning Signs to Act On Before Any Visit
Each of these calls for action at once, and for a service call only afterward:
- A gas smell. Leave the house with everyone in it. Do not switch lights or appliances on or off, use a phone indoors or start a car in an attached garage. From outside, call DTE Energy’s gas emergency line and 911.
- A carbon monoxide alarm. Get everyone outside into fresh air and call 911. Stay out until responders clear the house, and leave fuel-burning equipment off until it has been checked.
- A scorching or burning smell. Shut the system off at the thermostat and at its power switch, which often looks like a light switch on or near the furnace. With smoke or flame, leave and call 911.
- Water near the equipment. Shut off the system’s power at its switch or at the breaker before going near standing water.
Schedule a Diagnosis
Furnace, boiler, air conditioner or heat pump, the work begins the same way: with the cause found before any part is ordered.